IS130-6GP
Industrial Ethernet Gigabit Unmanaged Layer 2 Switch
Intended for use in outdoor IoT, city-wide surveillance, transportation and general industrial applications, the IS130-6GP unmanaged Layer 2 switch is engineered for simple operation, easy deployment, and reliable operation in harsh environments.
Key Features
- Wide operating temp range: -40°C to 75°C supports outdoor operation
- Fanless, with air convection cooling for high reliability
- Includes DIN-rail and wall mounting options for easy installation
- 5 x 10/100/1000T fixed ports + 1 x SFP slot, with PoE available on 4 ports
- PoE+ power up to 30W per port, with an overall power budget of 90W
- Dual power input with reverse polarity and current overload protection
Specifications
Product | 10/100/1000T (RJ-45) Copper Ports | 100/1000X SFP Ports | PoE Enabled Ports | Switching Fabric | Forwarding Rate |
---|---|---|---|---|---|
IS130-6GP | 5 | 1 | 4 | 12Gbps | 8.93Mpps |
Physical
Product | Width x Depth x Height | Weight | Unpackaged Dimensions | Unpackaged Weight | Enclosure | Mounting | Protection Rate |
---|---|---|---|---|---|---|---|
IS130-6GP | 30 x 95 x 140 mm (1.18 x 3.74 x 5.51 in) | 500 g (1.10 lb) | 216 x 165 x 68 mm (8.50 x 6.50 x 2.68 in) | 700 g (1.54 lb) | Metal shell | DIN rail, wall mount | IP30 |
Power Characteristics
Product | Input Voltage | Cooling | No PoE Load Max Power Consumption | No PoE Load Max Heat Dissipation | No PoE Load Noise |
---|---|---|---|---|---|
IS130-6GP | 48Vdc* | Fanless | 14.0W @48Vdc | 47.9 BTU/h | - |
54Vdc** | Fanless | 19.6W @54Vdc | 66.9 BTU/h | - |
Power over Ethernet
Product | Full PoE Load*** Max Power Consumption | Full PoE Load*** Max Heat Dissipation | Full PoE Load*** Noise | PoE Power Budget | 15W Max PoE Sourcing Ports | 30W PoE+ Max PoE Sourcing Ports |
---|---|---|---|---|---|---|
IS130-6GP | 74.0W @48Vdc | 47.9 BTU/h | - | 60W @75°C | 4 | 2 |
109.6W @54Vdc | 66.9 BTU/h | - | 90W @75°C | 4 | 3 |
* sourcing IEEE 802.3af Type 1 (PoE)
** sourcing IEEE 802.3at Type 2 (PoE+)
*** The Max Power consumption at full PoE load includes PD’s consumption and margin. The cooling requirements of the switch are smaller than the power draw, because most of the load is dissipated at the PoE powered device (PD) and along the cabling. Use these wattage and BTU ratings for facility capacity planning.
Ordering Information
The DIN rail and wall mount kits are included.
AT-IS130-6GP-80
5x 10/100/1000T, 1x 100/1000X SFP combo,
Industrial Unmanaged Layer 2 Switch, POE+
Power Supplies
AT-IE048-240-20
240W @48Vdc, Industrial AC/DC power supply,
DIN rail mount (5 years warranty)
AT-SDR120-48
120W @48Vdc, Industrial AC/DC power supply,
DIN rail mount
AT-SDR240-48
240W @48Vdc, Industrial AC/DC power supply,
DIN rail mount