Backup and restore AMF Security mini
Describes how to backup and restore AMF Securitymini.
Backup AMF Security mini
To backup AMF Security mini, you need to get the following files:- System Settings
- Authentication Data
- AMF Security Log
- Action Log
System Settings
This is the setting of AMF Security mini itself.To get the system settings file, click the "Export" button in the "System Settings" item on the System Settings > System Information page.
However, the following items are not included in the system settings, so you need to reconfigure them after restoration. Prepare the corresponding file.
- SSL Certificate
"SSL Certificate" item on theSystem Settings > Network Settings page or AMF > AMF Application Proxy Settings page (they are on the two screens, but they are the same item)
- Trap Monitor Settings - Uploaded Rules
Rules uploaded in the "Rules" item on the System Settings > Trap Monitoring Settings page
Authentication Data
AMF Security mini authenticates based on the MAC Address information of the registered device, but registers it with AMF Security mini. The data required for this AMF Security mini authentication process is called Authentication Data.To get the authentication data, click the "Export" button in the "Authentication Data" item on the System Settings > System Information page.
AMF Security Log
This is a log message output by the AMF Security mini service. You can back it up, but you cannot restore it.To get the AMF Security log, click the "Download" button on the System Settings > AMF Security Log page.
Action Log
Of the log messages output by the AMF Security mini service, this is a log message related to Actions. You can back it up, but you cannot restore it.To get the Action Log, click the "Download" button on the System Settings > Action Log page.
AMF Security mini backup is complete.
Restore AMF Security mini
Describes how to restore AMF Securitymini.- SSL Certificate (Only when used)
Configure the "SSL Certificate" item on theSystem Settings > Network Settings page or AMF > AMF Application Proxy Settings page (they are on the two screens, but they are the same item).
- Trap Monitor Settings - Uploaded Rules (Only when used)
Upload the file in the "Rules" item on the System Settings > Trap Monitoring Settings page.
From here, execute in order.
- System Settings
Click the "Import" button in the "System Settings" item on the System Settings > System Information page to restore the acquired system configuration file.
- Restarting AMF Security mini instance (stop → start)
Refer to the x950 Series / x908GEN2 documentation for working with AMF Security mini instances.
- Authentication Data
Click the "Import" button in the "Authentication Data" item on the System Settings > System Information page to restore the acquired Authentication Data file.